Command sources specified by H30
Definition of Setting Value for H30
0
□
□
□
(hex)
Alternative settings as below are available.
- 0x0005 : Equivalent with 0x0030
- 0x0006 : Equivalent with 0x0033
- 0x000E : Equivalent with 0x0333
For details, refer to Chapter 1 "BLOCK DIAGRAMS FOR CONTROL LOGIC" and the
RS485 Communication User's Manual or CAN Communication User's Manual.
When the
LE
terminal command is assigned to a digital input terminal and the terminal is
ON, the settings of function code H30 are effective. When the terminal is OFF, the
settings of the function are ineffective, and both speed commands and run commands
specified from the inverter itself take control.
H42
Capacitance of DC Link Bus Capacitor
H42 displays the measured capacitance of the DC link bus capacitor (reservoir capacitor).
- Data setting range: 0 to 65535
H43
Cumulative Run Time of Cooling Fan
H43 displays the cumulative run time of the cooling fan in units of 10hours.
- Data setting range: 0 to 9999
H47
Initial Capacitance of DC Link Bus Capacitor
H47 displays the initial value of the capacitance of the DC link bus capacitor (reservoir capacitor).
- Data setting range: 0 to 65535
H48
Cumulative Run Time of Capacitors on Printed Circuit Board
H48 displays the cumulative run time of capacitors on the printed circuit boards in units of 10hours.
- Data setting range: 0 to 9999
0: inverter itself
1: RS-485 port 1
2: RS-485 port 2
3: CAN
4 to F: same as 0
Speed command
Run command
Torque bias command
2-94
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...