2.1 Function Code Tables
2-13
Chap. 2
FUNCTION C
O
DES
Code
Name
Data setting range
Incr
em
ent
Un
it
Ch
a
n
ge
wh
en
runni
n
g
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
o
n
wh
ich
ca
n b
e
used
U02 Customizable logic: Step 1
[Digital]
-
-
N
Y
100
1
Y
U03
(Input 1)
0 to 129: Same as E20 value.
-
-
N
Y
100
1
Y
(Input 2)
However, 27, 141 to 150 cannot be selected.
2001 to 2200 (3001 to 3200): Output of Step 1 to 200
4001 (5001): X1 terminal input signal
4002 (5002): X2 terminal input signal
4003 (5003): X3 terminal input signal
4004 (5004): X4 terminal input signal
4005 (5005): X5 terminal input signal
4006 (5006): X6 terminal input signal
4007 (5007): X7 terminal input signal
4008 (5008): X8 terminal input signal
4010 (5010): FWD terminal input signal
4011 (5011): REV terminal input signal
4101 (5101): X1 terminal input signal (only terminal)
4102 (5102): X2 terminal input signal (only terminal)
4103 (5103): X3 terminal input signal (only terminal)
4104 (5104): X4 terminal input signal (only terminal)
4105 (5105): X5 terminal input signal (only terminal)
4106 (5106): X6 terminal input signal (only terminal)
4107 (5107): X7 terminal input signal (only terminal)
4108 (5108): X8 terminal input signal (only terminal)
4110 (5110): FWD terminal state (only terminal)
4111 (5111): REV terminal state (only terminal)
8002:
Output
current
8003:
Output
voltage
8004:
Output
torque
8008:
Actual
speed/estimated
speed
8009: DC link bus voltage
8018:
Inverter
heat
sink
temperature
8019:
Inverter
internal
temperature
9001: Analog 12 terminal input signal
9002:
Analog C1 terminal input signal
9003: Analog V2 terminal input signal
U04
(Function 1)
-9990 to 0.00 to 9990
Variable
-
N
Y
0.00
12
Y
U05
(Function 2)
-9990 to 0.00 to 9990
Variable
-
N
Y
0.00
12
Y
Customizable logic Step 1 to 14 function code is assigned as follows: Setting value is the same as U01 to U05.
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Step 10
Step 11 Step 12 Step 13 Step 14
Block
selection U01 U06 U11 U16 U21 U26 U31 U36 U41 U46 U51 U56 U61 U66
Input
1
U02 U07 U12 U17 U22 U27 U32 U37 U42 U47 U52 U57 U62 U67
Input
2
U03 U08 U13 U18 U23 U28 U33 U38 U43 U48 U53 U58 U63 U68
Function
1
U04 U09 U14 U19 U24 U29 U34 U39 U44 U49 U54 U59 U64 U69
Function
2
U05 U10 U15 U20 U25 U30 U35 U40 U45 U50 U55 U60 U65 U70
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...