3.4.4.5 Check/Set travel direction counter function: “Travel Counter”
PRG > 3 > 5
This allows to check and set the travel direction counter (TDC) function.
For additional information about TDC function, refer to related Application Note
(AN-Lift2-0004v100EN).
3.4.5 Alarm Information: “Alarm Info”
PRG > 4
3.4.5.1 Check Alarm History: “Alarm History”
PRG > 4 > 1
For the most recent alarm and the past three, shows alarm codes indicating the types of protective functions
operated, the number of consecutive alarms, and the various inverter status at the time the alarm was
triggered.
Table 3.14 Display items in “Alarm History”
Page
No.
Category
Symbol
Details
1
Alarm name
—
Name of alarm
Main alarm
Main
Triggered alarm code and alarm sub-code which means
detailed causes of alarm.
For detail about alarm sub-code, please contact us.
Overlapping alarm 1
O.lap1
Simultaneously triggered alarm code (No. 1) and alarm
sub-code.
(If no alarm, shows " --- ")
Overlapping alarm 2
O.lap2
Simultaneously triggered alarm code (No. 2)
(If no alarm, shows " --- ")
2
Reference speed (pre-ramp)
Fref
Reference speed (pre-ramp) currently specified [Hz]
Reference speed (final)
Fout1
Reference speed (final) commanded to the Automatic Speed
Regulator (ASR) [Hz]
Speed
Speed
Detected speed [Hz]
Output current
Iout
Output current [A]
Output voltage
Vout
Output voltage [V]
Magnetic pole position
offset angle
PP.Ofs
Magnetic pole position offset angle [deg] at that time.
3
Calculated torque
Torque
Calculated torque [%]
Reference torque
TRQC
Value [%] based on the motor rated torque being at 100%.
Reference torque current
TRQI
Value [%] based on the motor rated current being at 100%.
4
Cumulative run time
Time
Shows cumulative time inverter’s main power has been on.
Reverts to 0 after exceeding 655,350 hours and begins
counting up again.
Number of startups
EneN
Accumulates and shows the number of motor operations (the
number of times the inverter run command has been ON).
Reverts to 0 after exceeding 6,553,500 times and begins
counting up again.
DC link bus voltage
Edc
Shows DC link bus voltage of inverter’s main circuit.
Interior temperature
T.Int
Shows the interior temperature.
Heat sink temperature
T.Fin
Shows the heat sink temperature.
Power consumption
Power
Power consumption (only the most recent alarm history
stored.)
3-26
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...