2-10
H codes: High Performance Functions
Code
Name
Data setting range
Incr
em
ent
Un
it
C
hang
e
w
h
en
runni
ng
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
control
Softw
ar
e ver
si
o
n
wh
ich
ca
n b
e
used
H03 Data Initialization
0: Disable initialization
-
-
N
N
0
1
Y
1: Initialize all function code data to the factory defaults
(vector control for IM)
2: Initialize all function code data to vector control for
PMSM
3: Initialize all function code data to open loop control for IM
11: Initialize all function code data to the factory defaults
without
Link
parameters
12: Initialize customizable logic parameters
H04
Auto-reset
(Times)
0:
Disable
1 to 10: Auto reset number of times
H05
(Reset interval)
0.5 to 20.0
0.1
s
Y
Y
5
3
Y
H06
Cooling Fan Control
Auto(0.0): Automatic ON/OFF depending upon temperature
0.1
min
Y
Y
Auto
3
Y
OFF(32767): Disable (Always ON)
0.5 to 10.0 min: OFF by timer
H26
PTC/NTC Thermistor
(Mode)
0:
Disable
1: Enable (Upon detection of (PTC), the inverter
immediately trips and stops with
0h4
displayed.)
2: Enable(Upon detection of (PTC), the inveter continues
running while outputting alarm signal TMH.)
3: Enable(Upon detection of (NTC), the inveter detects
motor
temperature)
H27
(Level) 0.00
to
5.00
0.01
V
Y
Y
1.60
5
Y
H30
Communications Link Operation
Each digit of hexadecimal number specifies the source of
-
-
Y
Y
0000
H
1
Y
following
commands.
Additionally, following alternative settings are also available
for compatibility with FRENIC-Lift (LM1):
0x0005 : Equivalent with 0x0030
0x0006 : Equivalent with 0x0033
0x000E : Equivalent with 0x0333
H42
Capacitance of DC Link Bus Capacitor
Meas(0): Initial value measurement
-
-
N
N
-
1
Y
Failed(1): Measurement failure
2 to 65535: Indication for replacing DC link bus capacitor
H43
Cumulative Run Time of Cooling Fan
0 to 9999: Indication of cumulative run time of cooling fan in
-
-
N
N
-
74
Y
10 hours for replacement
H47
Initial Capacitance of DC Link
0 to 65535: Indication for replacing DC link bus capacitor
-
-
N
N
Set at
1
Y
Bus Capacitor
factory
shipping
H48 Cumulative Run Time of Capacitors on 0 to 9999: Indication for replacing capacitors on printed circuit
-
-
N
N
-
74
Y
Printed Circuit Board
boards
H54
Acceleration Time
0.00
to
99.9
Variable
s
Y
Y
1.80
12
Y
(Jogging)
H55 Deceleration
Time
0.00
to
99.9
Variable
s
Y
Y
1.80
12
Y
(Jogging)
H56
Deceleration Time
0.00
to
99.9
Variable
s
Y
Y
1.20
12
Y
for Forced to Decelerate
H57
S-curve Setting 11
0 to 50% of max. speed
1
%
Y
Y
20
1
N
H58
S-curve Setting 12
1
%
Y
Y
20
1
N
H59
S-curve Setting 13
1
%
Y
Y
20
1
N
H60
S-curve Setting 14
1
%
Y
Y
20
1
N
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...