2.3 Overview of Function Code
C
hap.
2
FUN
CT
IO
N
C
O
D
E
S
F20
DC Braking(Starting Speed)
F21
DC Braking(Operation Level)
F22
DC Braking(Operation Time)
H64
(
Zero speed holding time)
The starting speed, the operation level, and the operation time of the DC braking are set. The DC
braking doesn't operate when using it by the vector control with PG.
■
DC Braking (Starting Speed)(F20)
The starting speed of the DC braking when decelerating to stop is set.
Data setting range changes depending on the number of poles of motor etc. For details, refer to
section 2.2.
■
DC Braking
(Operation Level)(F21)
Sets the output current of the DC braking. This level is used at start (during H64) and at stop (during
F22).
- Data setting range: 0 to 100 (%)
■
DC Braking
(Operation Time)(F22)
The operation time of the DC braking is set. This timer will start to count only when decelerating to
stop, in other words, when decelerating F20 speed level is reached. The stop speed operation is
carried out when set to 0.00 s.
- Data setting range: 0.00 to 30.00 (s)
Timing diagram at stop
Timing diagram at start
DC braking operates at the stop speed when the stop speed (F25) is bigger than DCB
starting speed (F20).
Reference speed
DC Brake
Output voltage
Motor speed
ON
OFF
OFF
0 Hz
0 V
0 rpm
F22
F21
F20
ON
OFF
OFF
0 Hz
0 V
0 rpm
H64
F21
F23
F24
H65
Reference speed
DC Brake
Output voltage
Motor speed
2-39
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...