P codes (Motor parameters)
2.3.4
P01
Motor (No. of poles)
P01 specifies the number of poles of the motor. The following formula is used for the conversion.
(Hz)
Frequency
×
poles
of
No.
120
(r/min)
speed
Motor
=
- Data setting range: 2 to 100 (poles)
Changing the P01 data requires modifying the data of some function codes. For details,
refer to section 2.2.
P02
Motor (Rated capacity)
P02 specifies the rated capacity of the motor. Enter the rated value shown on the nameplate of the
motor.
- Data setting range: 0.01 to 55.00 (kW)
P03
Motor (Rated current)
P03 specifies the rated current of the motor. Enter the rated value shown on the nameplate of the
motor.
- Data setting range: 0.00 to 500.0 (A)