2.3 Overview of Function Code
C
hap.
2
FUN
CT
IO
N
C
O
D
E
S
K20
K21
K22
Bar Chart 1 (Display item selection)
Bar Chart 2 (Display item selection)
Bar Chart 3 (Display item selection)
These function codes specify the items to be displayed in bar graphs 1 to 3 on the LCD monitor.
-Data setting range: 1 to 30
Data
Monitor item
LCD indicator
Definition of monitor amount 100%
1
Reference speed
(Final)
Spd
Rated Speed (F03)
13
Output current
Iout
Twice the inverter rated current
14
Output voltage
Vout
200 V class: 250 V
400 V class: 500 V
18
Calculated torque
TRQ
Twice the rated motor torque
19
Input power
PWR
The inverter rated capacity
28
Reference torque
TRQC
Twice the rated motor torque
29
Torque bias balance
adjustment (Offset) (BTBB)
BTBB
Twice the rated motor torque
30
Torque bias gain adjustment
(BTBG)
BTBG
Twice the rated motor torque
The monitor items for bar charts 1 to 3 can be selected easily in Programming mode as
follows.
PRG > 1(Start-up) > 3(Disp Setting) > 6(Bar Chart 1)
PRG > 1(Start-up) > 3(Disp Setting) > 7(Bar Chart 2)
PRG > 1(Start-up) > 3(Disp Setting) > 8(Bar Chart 3)
K23
Traveling direction selection
K23 specifies
the
relation between “FWD / REV” and “Upward / Downward” for keypad displaying.
Data for K23
moving FWD
moving REV
0
Upward
Downward
1
Downward
Upward
2-205
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...