2.1 Function Code Tables
2-9
Chap. 2
FUNCTION C
O
DES
P codes: Motor Parameters
Code
Name
Data setting range
Incr
em
ent
Un
it
Ch
a
n
ge
wh
en
runni
n
g
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
o
n
wh
ich
ca
n b
e
used
P01
Motor
(No. of poles)
2 to 100
2
Poles
N
Y1 Y2
4
1
Y
P02
(Rated capacity)
0.01 to 55.00
0.01
kW
N
Y1 Y2
Refer to
11
Y
default
table
P03
(Rated current)
0.00 to 500.0
Variable
A
N
Y1 Y2
Refer to
24
Y
default
table
P04
(Auto-tuning) 0:
Disable
-
-
N
N
0
21
Y
1: Enable (Tune %R1 and %X while the motor is stopped.)
2: Enable (Tune %R1, %X, no-load current, and rated slip
whilethe motor is stopped.)
3: Enabl (Tune %R1, %X and rated slip while the motor is
stopped. no-load current is calculated by the motor
constant)
4:
Enable
(Auto tuning current loop (ACR) proportional gain)
P06
(No-load current)
0.00 to 500.0
Variable
A
N
Y1 Y2
Refer to
24
Y
default
table
P07
(%R1) 0.00
to
50.00
0.01
%
Y
Y1 Y2
Refer to
5
Y
default
table
P08
(%X)
0.00
to
50.00
0.01
%
Y
Y1 Y2
Refer to
5
Y
default
table
P09
(Slip comp. driving gain)
0.0 to 200.0
0.1
%
Y
Y
100.0
3
Y
P10
(Slip comp. braking gain)
0.0 to 200.0
0.1
%
Y
Y
100.0
3
Y
P11
(Slip comp. response time)
0.05 to 1.00
0.01
s
Y
Y
1.00
5
Y
*8
P12
(Rated slip)
0.00: Rated slip of Fuji standard motor
0.01
Hz
Y
Y1 Y2
0.00
5
Y
0.01 to 15.00
P60
(Armature resistance - Rs)
0.000 to 50.000
0.001
Ohm
N
Y1 Y2
0.000
45
N
P62
(Armature q-axis reactance - Xs)
0.000 to 50.000
0.001
Ohm
N
Y1 Y2
0.000
45
N
P63
(Interphase inductive voltage - E)
0 to 500
1
V
N
Y1 Y2
0
1
N
*8 This function code is only for the torque vector control.
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...