2.3 Overview of Function Code
C
hap.
2
FUN
CT
IO
N
C
O
D
E
S
■
Operation Time Diagram
Main power
MC1
BATRY
MC2
73X
Battery power supply
DC link bus voltage Edc
Run command
Manual speed (middle)
Detected speed
Undervoltage level
C03
T1
T2
0.1 s
Battery operation
allowable zone
Zero speed
Zero speed
ON
ON
ON
ON
ON
ON
ON
ON
ON
S-curve acce./dece. disabled
E17
E17
0
L125
The time duration of T1 changes depending on the voltage and capacity. Refer to the description of
specifications (4).
■
Precautions
(1) The battery power supply must be connected before
BATRY
signal is turned ON. Alternatively
connect the battery power supply at the same time as turning ON
BATRY
signal.
(2) As shown above, inverter operation is possible within the battery operation allowable zone.
There must be a delay of the "T1 + T2" period from when the
BATRY
, MC, and battery power
supply are turned ON. After that the inverter becomes ready to run.
(3) The
BATRY
should not be turned ON as long as the voltage level is higher than the specified
undervoltage level (that is, before the
LV
appears after a power failure). Doing so blocks 73X to
go OFF.
(4) During battery operation, avoid operation with a driving load and run the elevator with a
balanced or regenerative load. Low battery voltage cannot generate sufficient torque and it
causes the motor to stall.
(5) These precautions are given for an inverter operation with an extremely low voltage that
prevents normal operation. For battery operation with a high voltage (such as 600 V for 400 V
class series inverter), do not use the
BATRY
but run the inverter in a normal manner at a low
speed and be careful with the battery capacity,
(6) In the case of normal operation, turn off
BATRY
. If the main power supply is turned ON with
BATRY
being ON, it could damage the inverter rectifier diode due to the inrush current by 73X
ON state.
2-79
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...