3.4.4.3 View Maintenance Information: “Maintenance”
PRG > 3 > 3
Displays information needed for inverter maintenance.
Table 3.13 Display items in “Maintenance”
Page
No.
Category
Code
Details
1
Cumulative run time
Time
Shows cumulative time inverter’s main power has been on.
Reverts to 0 after exceeding 65,535 hours and begins counting up
again.
DC link bus voltage
Edc
Shows DC link bus voltage of inverter’s main circuit.
Maximum effective
current value
Imax
Shows as the effective value the maximum inverter output current
each hour.
Cumulative power level
Wh
Shows cumulative power level. Reverts to 0 after passing
1,000,000 kWh.
2
Number of starting motor
(gate-on)
G-On
Accumulates and shows the number of motor operations (the
number of times the inverter run command has been ON). The
number 1.00 means 10000.
Number of power up
P-On
Shows the total amount of number the inverter has been turned
power on. The number 1.00 means 10000.
Powered life of cooling fan
EneT
Shows the total amount of time the cooling fan has been in
operation. Time when the cooling fan ON-OFF control (function
code H06) is enabled and the cooling fan is off is not counted.
Target life of cooling fan
Life
Shows the cooling fan’s remaining service life. Remaining life is
calculated by subtracting elapsed time from the service life (five
years).
3
Capacity of main circuit
capacitor
Cap
Current capacity of main circuit capacitor is shown, using capacity
at time of shipment as 100%.
Life of electrolytic
capacitor on PCB
(Powered life)
EneT
Shows as cumulative run time the product of the cumulative
amount of time during which a voltage has been applied to the
electrolytic capacitor on the PCB times a coefficient to account for
ambient temperature conditions.
Target life of electrolytic
capacitor on PCB
Life
Shows the remaining life of the electrolytic capacitor on the PCB.
Remaining life is calculated by subtracting elapsed time from the
service life (five years).
4
Cumulative motor run
time
EneT
Shows the motor’s cumulative run time. Reverts to 0 after
exceeding 99,990 hours and begins counting up again.
Number of startups
EneN
Accumulates and shows the number of motor operations (the
number of times the inverter run command has been ON). Reverts
to 0 after exceeding 65,535 times and begins counting up again.
5
Interior temperature
(Real-time value)
Int
Shows the current temperature inside the inverter.
Maximum interior
temperature
Int(max) Shows the maximum temperature inside the inverter in one-hour
increments.
Heat sink temperature
(Real-time value)
Fin
Shows the current temperature of the heat sink inside the inverter.
Maximum heat sink
temperature
Fin(max) Shows the current temperature of the heat sink inside the inverter.
3-23
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...