2.3 Overview of Function Code
C
hap.
2
FUN
CT
IO
N
C
O
D
E
S
■
Output signals (Digital,analog)
In the customizable logic, outputs from steps 1 to 10 are issued to SO001 to SO200, respectively.
SO001 to SO200 differ in configuration depending upon the connection destination, as listed below.
To relay those outputs to any function other than the customizable logic, route them via customizable
logic outputs CLO1 to CLO10.
Connection destination of each
step output
Configuration
Function
code
Input of customizable logic
Select one of the internal step output signals
“SO001” to “SO200” in customizable logic input
setting.
Such as U02
and U03
Input of inverter sequence
processor
(such as multistep speed “SS1”
or operation command “FWD”)
Select one of the internal step output signals
“SO001” to “SO200” to be connected to
customizable logic output signals 1 to 10 (“CLO1”
to “CLO10”).
U71 to U80
Select an inverter’s sequence processor input
function to which one of the customizable logic
output signals 1 to 10 (“CLO1” to “CLO10”) is to
be connected (same as in E01).
U81 to U90
Analog input
(such as
Speed command)
Select one of the internal step output signals
“SO01” to “SO200” to be connected to
customizable logic output signals 1 to 10 (“CLO1”
to “CLO10”).
U71 to U80
Select an analog input function to which one of the
customizable logic output signals 1 to 10 (“CLO1”
to “CLO10”) is to be connected (same as in E61).
U81 to U90
General-purpose digital output
([Y] terminals)
Select one of the internal step output signals
“SO001” to “SO200” to be connected to
customizable logic output signals 1 to 10 (“CLO1”
to “CLO10”).
U71 to U80
To specify a general-purpose digital output function
(on [Y] terminals) to which one of the customizable
logic output signals 1 to 10 (“CLO1” to “CLO10”)
is to be connected, select one of “CLO1” to
“CLO10” by specifying the general-purpose digital
output function on any Y terminal.
E20, E21,
E27
General-purpose analog output
([FMA] terminals)
Select one of the internal step output signals
“SO001” to “SO200” to be connected to
customizable logic output signals 1 to 10 (“CLO1”
to “CLO10”).
U71 to U80
To specify a general-purpose analog output
function (on [FM] terminals) to which one of the
customizable logic output signals 1 to 10 (“CLO1”
to “CLO10”) is to be connected, select one of
“CLO1” to “CLO10” by specifying the
general-purpose digital output function on any
[FM] terminal.
F31
General-purpose digital outputs (on [Y] terminals) are updated every 5 ms. To securely
output a customizable logic signal via [Y] terminals, include on- or off-delay timers in the
customizable logic. Otherwise, short ON or OFF signals may not be reflected on those
terminals.
2-127
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...