2.3 Overview of Function Code
C
hap.
2
FUN
CT
IO
N
C
O
D
E
S
■
Function 1 (U04, U09, etc.)(Digital)
Function 1 specifies the general-purpose timer period or the increment/decrement counter value.
Data
Function
Description
0.00 to +600.00
Timer
The period is specified in seconds.
Counter value The specified value is multiplied by 100 times.
(If 0.01 is specified, it is converted to 1.)
-9990.00 to -0.01
—
The timer or counter value works as 0.00. (No timer)
+601.00 to +9990.00
Timer
The period is specified in seconds.
[Input: analog] Block function code setting
■
Block selection, function 1, function 2 (U01, U04, U05, U06, U09, U10, etc.)(Analog)
The following items are available as function block operation.
Note that if the upper and lower limits have the same value, no upper and lower limits are applied.
Block
selection
(U01
etc.)
Function
block
Description
Function
1 (U04
etc.)
Function
2 (U05
etc.)
0
No function
assigned
This function always outputs 0% (or logical “0:
False”; OFF).
Not
required
Not
required
2001
Adder
Addition function with two inputs (input 1 and
input 2).
This function has output limiters (upper/lower)
specified with two function codes.
The 1st function code provides upper limit value
and the 2nd one provides lower limit value.
Upper
limit
Lower
limit
2002
Subtracter
Subtraction function with two inputs (input 1 and
input 2).
This function has output limiters (upper/lower)
specified with two function codes.
The 1st function code provides upper limit value
and the 2nd one provides lower limit value.
Upper
limit
Lower
limit
2003
Multiplier
Multiplication function with two inputs (input 1
and input 2).
This function has output limiters (upper/lower)
specified with two function codes.
The 1st function code provides upper limit value
and the 2nd one provides lower limit value.
Upper
limit
Lower
limit
2004
Divider
Division function with two inputs (input 1 and
input 2).
Input 1 is dividend and input 2 is divisor. This
function has output limiters (upper/lower)
specified with two function codes.
The 1st function code provides upper limit value
and the 2nd one provides lower limit value.
Upper
limit
Lower
limit
2005
Limiter
Upper and lower limit functions of single input
(input 1).
The 1st function code provides upper limit value
and the 2nd one provides lower limit value.
Upper
limit
Lower
limit
2006
Absolute
value of
input
Absolute value function of single input (input 1).
Negative input numbers become positive.
This function has output limiters (upper/lower)
specified with two function codes.
The 1st function code provides upper limit value
and the 2nd one provides lower limit value.
Upper
limit
Lower
limit
2-117
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...