C
hap.
3
O
P
E
R
AT
IO
N
U
S
IN
G
"T
P
-A1
-LM
2"
Page
No.
Category
Symbol
Details
5
Output status
FWD
Rotating forward
REV
Rotating reverse
EXT
Inverter applies DC voltage to the motor
INT
Inverter stops output
Ramp status
Acc
During acceleration
Dec
During deceleration
Const
During constant speed
<Blank>
Stopped
Motor type
IM
Induction motor (asynchronous motor)
PMSM
Permanent magnet synchronous motor
Selected control mode
PG-IM
Vector control with PG for IM
PG-PM
Vector control with PG for PMSM
TV
Torque vector (open loop) control for IM
Running status
PG/Hz
: Enable vector control
TrqLimit
: During torque limitation
LowVolt
: During low supply voltage
6
Operational status
FAR
: Frequency attained
Frequency detection
FDT
: Frequency detection
Run preparation
RDY
: Ready to run
Recovering power after
momentary power failure
FAN
: Cooling fan operating
Motor overload
TRY
: Trying automatic resetting alarm
Fan operating
OH
: Overheat early warning
Retrying
LIFE
: Lifetime warning
Heat sink overheat early
warning
ID
: Current detection
Lifetime alarm
ID2
: Current detection 2
Overload prevention
controlled
OLP
Overload prevention controlled
Current detection
ID
Current detection
7
Di:
Control circuit terminal
input signal (terminal input)
FWD, REV,
X1-X8,
EN1, EN2
ON/OFF information on control circuit’s terminal input
(Reversal on short-circuit, no reversal when open)
8
Di Link:
Communications port input
signal
FWD, REV,
X1-X8,
XF, XR, RST
Input information on communication-specific function code
S06
(Reversal on 1, no reversal on 0)
9
Do:
Output signal
Y1-Y2,
Y3A-Y5A,
30ABC
Output signal information
3-27
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...