L87
Door Control (Door open starting speed)
L88
Door Control (Door open delay time)
L89
Door Control (Door open period)
L87 to L89 specify the door open parameters relating to the door control signal
DOPEN
that is
assigned to a general-purpose, programmable output terminal by setting "78" with E20 to E24 and
E27.
■
Door open starting speed (L87)
L87 specifies the reference speed (final) below which the door control signal
DOPEN
is turned ON.
The
DOPEN
is turned ON actually after the door open delay time specified by L88 elapses.
- Data setting range: 0.00 to 6000 (r/min)
Data setting range changes depending on the number of poles of motor etc. For details, refer to
section 2.2.
■
Door open delay time (L88)
L88 specifies the delay time from when the speed drops below the door open starting speed (L87)
until the
DOPEN
signal is turned ON.
- Data setting range: 0.0 to 10.0 (s)
■
Door open period (L89)
L89 specifies the period during which the
DOPEN
is kept ON.
- Data setting range: 0.1 to 30.0 (s)
Door control
When the reference speed (final) drops below the door open starting speed (L87) during deceleration
and the door open delay time (L88) elapses, the
DOPEN
is turned ON and kept ON during the door
open period (L89).
Time
Speed
L88
:
Door control
(Door open
delay time)
L89
:
Door control
(Door open
period)
Digital output
DOPEN
ON
L87
:
Door control
(Door open
starting speed)
OFF
Increasing the reference speed (final) above the speed (L87) with the
DOPEN
being OFF activates
the
DOPEN
ON process judgment. If the reference speed (final) does not exceed the speed (L87),
the L88 and L89 specifications will be ignored so that the
DOPEN
will be kept OFF.
Decreasing the reference speed (final) from the speed exceeding the L87 down to less than the L87
activates the delay timer (L88). After the delay time (L88) elapses, the
DOPEN
turns ON during the
door open period (L89).
This door control applies to also the battery operation. When the battery operation speed does not
reach the door open starting speed (L87), the
DOPEN
will be kept OFF.
Note: When the L87 = 0.00, the
DOPEN
does not work. Operation is different according to L99
bit6.
Refer to the descriptions of function codes L99 bit6 for details.
2-170
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...