3.3 Running Mode
When the inverter is turned on, it automatically enters Running mode in which you can:
(1) Monitor the running status (e.g., reference speed and output current),
(2) Switch between remote and local modes,
(3) Configure the reference speed (pre-ramp), and
(4) Run/stop the motor.
3.3.1 Monitoring the running status
In Running mode, the nine items listed below can be monitored. Immediately after the inverter is
turned on, the monitor item specified by function code K10 is displayed. Press the key to switch
between monitor items.
Table 3.5 Monitoring Items (Selectable anytime)
Monitor
#
Monitor Items
Sub-
monitor
Unit
Meaning of displayed value
Function
code data
for E43
0
Speed monitor
Function code E48 specifies what to be displayed on the main monitor.
0
Reference speed
(final)
Spd
*1
Reference speed (final) command to the
Automatic speed regulator (ASR)
(E48 = 0)
Reference speed
(pre-ramp)
S.Spd
*1
Reference speed being set
(E48 = 2)
Motor speed
Sync
r/min Motor rotation speed
(E48 = 3)
Elevator speed
Lift
m/min Elevator speed in m/min
(E48 = 5)
Elevator speed 2
Lift
mm/s
Elevator speed in mm/s
(E48 = 8)
13
Output current
Iout
A
Current output from the inverter in RMS
3
14
Output voltage
Vout
V
Voltage output from the inverter in RMS
4
18
Calculated torque
TRQ
%
Calculated motor output torque in % *2
8
19
Input power
PWR
kW
Input power to the inverter
9
28
Reference torque
TRQC
%
Motor output torque in %
18
29
Torque bias balance
adjustment value
BTBB
%
Used to adjust the analog torque bias balance
19
30
Torque bias gain
adjustment value
BTBG
%
Used to adjust the analog torque bias gain
20
*1 Function code C21 provides a choice of speed units – Hz, r/min, m/min, and mm/s.
*2 In vector control with PG, this item shows the reference torque.
Figure 3.4 Switching main monitor item (display example)
1450
r/
min
REM
PRG
Cancel
Speed
<Main Monitor>
Speed
RESET
T-Bias Gain
Output Current
1.
30.
13.
3-6
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...