2.1 Function Code Tables
2-21
Chap. 2
FUNCTION C
O
DES
K codes: Keypad Functions (optional)
Code
Name
Data setting range
Incr
em
ent
Un
it
Ch
a
n
ge
wh
en
runni
n
g
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
o
n
wh
ich
ca
n b
e
used
K01 LCD Monitor
(Language selection)
0: Japanese
1:
English
- -
Y
Y
1
*2
1 Y
2:
German
3:
French
4:
Spanish
5:
Italian
6:
Chinese
8:
Russian
9:
Greek
10: Turkish
11: Polish
12: Czech
13: Swedish
14: Portuguese
15: Dutch
100: User-customizable
0400
K02
(Backlight off time)
OFF (0.00): Always OFF
1 to 30: Automatic OFF after specific minutes from last key-in
1 min
Y Y 5 1 Y
K03
(Backlight brightness control)
0 (Dark) to 10 (Light)
1
-
Y
Y
5
1
Y
K04
(Contrast control)
0 (Low) to 10 (High)
1
-
Y
Y
15
1
Y
K08
(Status Display/Hide Selection)
0: Hide
1: Display
- - Y Y 1 1 Y
K15
(Status Display/Hide Selection)
0: Numeric values (2x programable sub monitors)
1: Bar charts (3x programable bar charts)
- - Y Y 0 1 Y
K16
(Sub
monitor
1)
-
-
Y
Y
13
1
-
K17
(Sub
monitor
2)
-
-
Y
Y
19
1
-
1:
Reference
speed
(Final)
Y
3:
Reference
speed
(pre-ramp)
Y
4:
Motor
speed
Y
*5
6:
Elevator
speed
Y
*5
9:
Elevator
speed
(mm/s)
Y
*5
13:
Output
current
Y
14:
Output
voltage
Y
18:
Calculated
torque
Y
19:
Input
power
Y
28:
Reference
torque
N
29: Torque bias balance adjustment (Offset) (BTBB)
N
30: Torque bias gain adjustment (BTBG)
N
K20
(Bar
chart
1)
-
-
Y
Y
1
1
-
K21
(Bar
chart
2)
-
-
Y
Y
13
1
-
K22
(Bar
chart
3)
-
-
Y
Y
19
1
-
1:
Reference
speed
(Final)
Y
13:
Output
current
Y
14:
Output
voltage
Y
18:
Calculated
torque
Y
19:
Input
power
Y
28:
Reference
torque
N
29: Torque bias balance adjustment (Offset) (BTBB)
N
30: Torque bias gain adjustment (BTBG)
N
K23
(Traveling direction display)
0: FWD = UP direction
1: REV = UP direction
- - Y Y 0 1 Y
K91
(< key shortcut selection)
0: OFF (Disable)
11 to 99: Enable shortcut function to each display mode
* For example, "21" means "PRG>2>1".
- - Y Y 0 1 Y
K92
(> key shortcut selection)
-
-
Y
Y
0
1
Y
*2 The factory default setting varies depending on the shipping destination.
*5 It is indicated depending on reference speed (final).
Default Table
Type
P02
F11,E34,E37,P03
P06
P07
P08
FRN0006LM2A-4_ 2.20[kW]
5.50[A] 3.40[A]
6.82[%]
9.91[%]
FRN0010LM2A-4_ 3.70[kW]
9.00[A] 5.70[A]
5.54[%]
8.33[%]
FRN0015LM2A-4_ 5.50[kW]
13.50[A] 8.40[A] 4.05[%]
11.72[%]
FRN0019LM2A-4_ 7.50[kW]
18.50[A] 9.80[A] 4.23[%]
13.01[%]
FRN0025LM2A-4_ 11.00[kW]
24.50[A] 13.90[A]
3.22[%]
12.27[%]
FRN0032LM2A-4_ 15.00[kW]
32.00[A] 17.90[A]
2.55[%]
11.47[%]
FRN0039LM2A-4_ 18.50[kW]
37.00[A] 16.20[A]
1.98[%]
11.97[%]
FRN0045LM2A-4_ 22.00[kW]
45.00[A] 19.00[A]
2.11[%]
12.35[%]
FRN0060LM2A-4_ 30.00[kW]
58.00[A] 21.40[A]
2.14[%]
14.62[%]
FRN0075LM2A-4_ 37.00[kW]
72.00[A] 30.80[A]
1.86[%]
11.99[%]
FRN0091LM2A-4_ 45.00[kW]
85.00[A] 31.10[A]
1.96[%]
13.40[%]
FRN0011LM2A-7_ 2.20[kW]
11.00[A] 7.20[A] 6.82[%]
9.91[%]
FRN0018LM2A-7_ 3.70[kW]
18.00[A] 11.40[A]
5.54[%] 8.33[%]
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...