2-136
y21 to y37
Built-in CANopen communication setting
For details, refer to the CAN Communication User’s Manual.
■
Node-ID (y21)
Set the node-ID for CANopen communication. The setting range is 1 to 127.
■
Baud rate (y24)
Sets the transmission baud rate for CAN communication.
y24 data
Function
0 10
kbit/s
1 20
kbit/s
2 50
kbit/s
3 125
kbit/s
4 250
kbit/s
5 500
kbit/s
6 800
kbit/s
7 1
Mbit/s
■
User-defined I/O parameter 1 to 8 (y25-y32)
y25 to y28 : Sets the inverter function code (write) to be mapped to RPDO No.3
y29 to y32 : Sets the inverter function code (read) to be mapped to TPDO No.3
Specify the function code type and number in a 4-digit hexadecimal notation.
□
□
□
□
Type Group
code Type Group
code
S 0x02(2) X1
0x1A(26)
M 0x03(3) X2 0x1B(27)
F 0x04(4) Z1
0x1C(28)
E 0x05(5) K 0x1D(29)
C 0x06(6) E1 0x1F(31)
P 0x07(7) H1
0x20(32)
H 0x08(8) U1 0x22(34)
L 0x0B(11) M1 0x23(35)
U
0x0D(13) U2 0x37(55)
y 0x0F(15) L1 0x38(56)
W 0x10(16) L2 0x39(57)
X 0x11(17) L3 0x3A(58)
Z 0x12(18) L4 0x3B(59)
W1 0x17(23) L5 0x3C(60)
W2 0x18(24) L6 0x3D(61)
W3 0x19(25)
■
Operation selection (y33)
Sets the operation selection for CAN communication.
y33 data
Function
0 Disable
1
CANopen CiA 402 Enable
Function code No. (refer to the description of function code y37)
Function code type (see the table below)
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...