L66
Unbalanced load compensation (Activation time)
L56 (Torque Bias, Reference torque end time)
L65 (Unbalanced Load Compensation, Operation)
L66 specifies the calculation time duration of unbalanced load compensation after the
UNBL
command is turned ON.
- Data setting range: 0.01 to 2.00 (s)
Refer to the descriptions of function codes L56 and L65 for details.
L68
Unbalanced load compensation (ASR P constant)
L68 specifies the ASR(Automatic Speed Regulator) P constant used in unbalanced load calculation.
Set a larger constant than the one specified in normal operation. If vibration occurs, decrease it.
- Data setting range: 0.00 to 200.00
L69
Unbalanced load compensation (ASR I constant)
L69 specifies the ASR I constant used in unbalanced load calculation.
Set a smaller constant than the one specified in normal operation. If vibration occurs, increase it.
- Data setting range: 0.001 to 1.000 (s)
L73
Unbalance load compensation (APR P constant)
L73 specifies the APR (Automatic Position Regulator) P constant used in unbalanced load
calculation. If vibration occurs, decrease it.
- Data setting range: 0.00 to 10.00
L74
Unbalance load compensation (APR D constant)
L74 specifies the APR D constant used in unbalanced load calculation.
- Data setting range: 0.0 to 10.0
L75
Unbalance load compensation (Filter Time Constant for Detected Speed)
L75 specifies the filter time constant for detected speed used in unbalanced load calculation.
- Data setting range: 0.000 to 0.100 (s)
L76
Unbalance load compensation (ACR P constant)
L76 specifies the ACR (Automatic Current Regulator) P constant used in unbalanced load
calculation. If vibration occurs, decrease it. In case L76 is set to 0.0, L05 setting value is used for
ACR P constant during unbalanced load calculation.
- Data setting range: 0.0 (L05 setting value)
0.1 to 10.0
2-163
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...