3.4.3.4 Copying function code data: Data Copy”
PRG > 2 > 4
This menu provides “Read”, “Write”, “Verify”, and “Check” operation, enabling the following
applications. The keypad can hold three sets of function code data in its internal memory to use for
three different inverters.
(a) Reading function code data already configured in an inverter and then writing that function code
data altogether into another inverter.
(b) Copying the function code data saved in the inverter memory into the keypad memory for backup.
(c) Saving function code data in the keypad as master data
for data management; that is, saving more
than one set of function code data in the keypad and writing a set of data suited to the machinery
into the target inverter.
(a) Copy
(b) Backup
(c) Data management
The following functions can be made to sub-menu numbers 1 to 5.
Table 3.9 Operations available in copying function code data
Sub-Menu
No
Sub-Menu
Description
1
I.Write: Write data with
verification after initialization
Performs inverter initialization, data writing, and verifying
automatically.
2
Read: Read data
Reads out function code data from the inverter memory and stores
it into the keypad memory.
3
Write: Write data
Writes the data held in the selected area of the keypad memory
into the target inverter memory.
4
Verify: Verify data
Verifies the data held in the keypad memory against that in the
inverter memory.
5
Check: Check copied data in the
keypad
Shows the model info (type) and function code data of three sets
of data stored in the keypad memory.
3-15
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...