In case of Reference speed (final) < Allowable speed (L30) and Holding time (L29) = OFF
when a deceleration command is entered
(1) Upon receipt of a deceleration command, an S-curve operation with L25
×
0.2 starts for
finishing the current acceleration after L30 allowable speed is reached.
(2) After completion of the S-curve operation, the inverter decelerates in an S-curve operation with
L25
×
0.2 to the creep speed.
High speed
Time
Speed
ON
ON
ON
ON
ON
Zero speed
Creep speed
L30: Short floor
operation
(Allowable speed)
Zero speed
command
High speed
command
Creep speed
command
Zero speed
command
L19
L28
L28
L26
E13
E12
L25x0,2
L24
FWD
SS1
SS2
SS4
L25x0,2
E14
In case of Reference speed (final)
≧
Allowable speed (L30) and Holding time (L29) = OFF
when a deceleration command is entered
(1) Upon receipt of a deceleration command, an S-curve operation with L25
×
0.2 starts for
finishing the current acceleration.
(2) After completion of the S-curve operation, the inverter decelerates in an S-curve operation with
L25
×
0.2 to the creep speed.
High speed
Time
Speed
ON
ON
ON
ON
ON
Zero speed
Creep speed
L30: Short floor
operation
(Allowable speed)
Zero speed
command
High speed
command
Creep speed
command
Zero speed
command
L19
L28
L28
L26
E13
E12
L25x0,2
L24
FWD
SS1
SS2
SS4
L25x0,2
E14
2-146
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...