2.3 Overview of Function Code
C
hap.
2
FUN
CT
IO
N
C
O
D
E
S
[Input: digital, analog] Block function code setting
■
Block selection, function 1, function 2 (U01, U04, U05, etc.) (digital,analog)
The following items are available as function block.
Note that if the upper and lower limits are identical, no upper and lower limits are applied.
Block
selection
(U01 etc.)
Function
block
Description
Function 1
(U04 etc.)
Function 2
(U05 etc.)
4001
Hold
Function to hold analog input 1 based on
digital input 2 state.
Upper
limit
Lower
limit
4002
Inverting
adder with
enable
Function investing addition function to analog
input 1 based on digital input 2 state.
Subtracted
value
(former)
Addition
value
(latter)
4003
Selector 1
Function to select analog input 1 and setting
value based on digital input 2.
Setting
value
Not
required
4004
Selector 2
Function to select setting value 1/2 based on
digital input 2 state.
Setting
value 1
Setting
value 2
4005
LPF
(Low pass
filter) with
enable
Value of analog input 1 is filtered through LPF
(time constant U04) when the digital input 1 is
“1”. When the digital input 1 is “0”, the analog
input 1 is directly output.
LPF maintains the previous output value.
Therefore, when the digital 1 input changes
from 0 to 1, the output will be the value with
the previous output value added as the initial
value of LPF.
(No upper/lower limiter)
Time
constant
0: No filter
0.01 to
5.00s
Fixed as 0
4006
Rate limiter
with enable
Value of analog input 1 is limited with change
rate specified in functions 1 and 2 when the
digital input 1 is “1”. When the digital input 1
is “0”, the analog 1 input is directly output.
When setting the initial value, carry out an
operation with the initial value for input 1 and
0 applied to input 2. Then, reflect the result as
the initial value (= previous output value) with
1 applied to input 2.
During the initialization or when the CLC
terminal is ON, the previous output value is
cleared to 0.
Upward
change rate
Time taken
to change
100%
0: Same
change rate
as function
1
0.01 to 600
s
Downward
change rate
Time taken
to change
100%
0: Same
change rate
as function
1
0.01 to 600
s
5000
Selector 3
Function to select analog input 1 or based on
“SO001” to “SO200”.
Step No.
Not
required
5100
Selector 4
Function to select analog input 1 or “SO001”
to “SO200” based on digital input 2.
Step No.
Not
required
2-123
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...