K16
K17
Sub Monitor 1 (Display item selection)
Sub Monitor 2 (Display item selection)
K16 and K17 specify the monitoring item to be displayed on the sub monitor 1 and 2.
-Data setting range: 1 to 30
Data
Function (Item to be displayed)
LCD
indicator
Unit
Description
1
Reference speed (final)
Spd
selected
by C21
-
3
Reference speed (pre-ramp)
S.Spd
selected
by C21 -
4
Motor speed
Sync
r/min
-
6
Elevator speed
Lift
m/min
-
9
Elevator speed (mm/s)
Lift
mm/s
-
13
Output current
Iout
A
Inverter output current expressed in
RMS (A)
14
Output voltage
Vout
V
Inverter output voltage expressed in
RMS (V)
18
Calculated torque
TRQ
%
Reference torque (%) based on the
motor rated torque *1
19
Input power
PWR
kW
Inverter's input power (kW)
28
Reference torque
TRQC
%
Torque in % based on the motor rated
torque being at 100%
29
Torque bias balance (Offset) adjustment
(BTBB)
BTBB
%
Used to adjust the analog torque bias
balance
30
Torque bias gain adjustment (BTBG)
BTBG
%
Used to adjust the analog torque bias
gain
*
1
In vector control with PG, this item shows the reference torque.
The monitor items of sub monitors 1 and 2 can be selected easily in Programming mode as
follows.
PRG > 1(Start-up) > 3(Disp Setting) > 4(Sub Monitor 1)
PRG > 1(Start-up) > 3(Disp Setting) > 5(Sub Monitor 2)
2-204
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...