2-4
The following tables list the function codes available for the FRENIC-Lift (LM2A) series of inverters.
F codes: Fundamental Functions
Code
Name
Data setting range
Incr
em
ent
Un
it
Ch
a
n
ge
wh
en
runni
ng
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
control
Softw
ar
e ver
si
o
n
wh
ich
ca
n b
e
used
F00 Data Protection
0: Disable data protection
(Function code data can be edited)
1: Enable data protection
Note: This setting is effective if H99 = 0000
H
.
- -
Y
N
0
1
Y
(Password
entry)
0001
H
to FFFF
H
Note: This setting is effective if H99 = other than 0000
H
.
Data of H99 is your password
F01 Frequency Command
0: Multistep speed command (
SS1
,
SS2
,
SS4
,
SS8
)
1: Analog speed command (Not reversible)
2: Analog speed command (Reversible)
3: Analog multistep speed command
- -
N
Y
0
1
Y
F03 Rated speed
30.0 to 6000
*1
(Equivalent with 1.00 to 200.00 Hz)
Variable
r/min
N
Y
1450
*2
37 Y
F04 Base speed
30.0 to 6000
*1
(Equivalent with 1.00 to 200.00 Hz)
Variable
*3
N
Y
1500
37
Y
F05 Rated Voltage
80 to 240 (for 200 V class series)
1
V
N
Y2
230
1
Y
160 to 500 (for 400 V class series)
380
F07 Acceleration/Deceleration Time 1
0.00 to 99.9
Note: Acceleration/Deceleration time is ignored at 0.00.
Variable
s Y Y
1.80
12 Y
F08 Acceleration/Deceleration
Time
2
Variable
s Y Y
1.80
12 Y
F09 Torque boost
0.0 to 5.0
0.1
-
Y
Y
*9
3
Y
*8
F10 Electronic
Thermal
Overload
Protection
for Motor
(Select motor characteristics)
1: For general-purpose motors with built-in self-cooling fan
2: For inverter-driven motors or high-speed motors with
forced-ventilation fan
3: For general-purpose motors with built-in self-cooling fan
(Mode2)
- -
Y
Y
2
1
Y
500
F11
(Overload detection level)
OFF (0.00): Disable
1 to 200% of the rated current (allowable continuous drive
current) of the inverter
Variable
A Y
Y1
Y2
Refer
to
default
table
24 Y
F12
(Thermal time constant)
0.5 to 75.0
0.1
min
Y
Y
2.0
3
Y
F20 DC Braking
(Starting Speed)
0.00 to 150.0
*1
(Equivalent with 0.00 to 5.00 Hz)
Variable
*3
N
Y
0.0
37
Y
*8
F21
(Braking Level)
0 to 100
1
%
N
Y
0
1
Y
*8
F22
(Braking
Time) OFF
(0.00):
Disable
0.01 to 30.00
0.01 s N Y
OFF
5 Y
*8
F23 Starting Speed
0.00 to 150.0
*1
(Equivalent with 0.00 to 5.00 Hz)
Variable
*3
N
Y
0.00
37
Y
F24
(Holding time)
0.00 to 10.00
0.01
s
N
Y
0.80
5
Y
F25 Stop Speed
0.00 to 150.0
*1
(Equivalent with 0.00 to 5.00 Hz)
Variable
*3
N
Y
3.00
37
Y
F26 Motor Sound
(Carrier frequency)
5 to 16
1
kHz
N
Y
15
1
Y
F30 FMA Terminal
(Output gain)
0 to 300
1
%
Y
Y
100
1
Y
F31
(Function
selection)
-
-
Y
Y
0
1
-
0:
Reference
speed
(Final)
Y
1:
Primary
frequency
Y
2:
Output
current
Y
3:
Output
voltage
Y
4:
Output
torque
Y
8:
Actual
speed
N
9: DC link bus voltage
Y
10:
Universal
AO
Y
14:
Calibration
(+)
Y
18: Inverter heat sink temperature
Y
19: Inverter internal temperature
Y
111: Customizable logic output signal 1
to
120: Customizable logic output signal 10
Y
F42 Control Mode
0: Vector control with PG for asynchronous motor
1: Vector control with PG for synchronous motor
2: Torque vector control
- -
N
Y
0
1
Y
F44 Current Limiter
(Level)
Auto(32767): Maximum current of each inverter automatically
applies.
100 to 230 (Percentage to the rated current of the inverter)
1 %
Y Y
Auto
1 N
F50 Electronic thermal overload protection
for braking resistor
(Discharging
capacity)
OFF(32767): Disable
1 to 9000
1 kWs
Y
Y1
Y2
OFF
1 Y
F51
(Allowable average loss)
0.001 to 99.99
Variable
kW
Y
Y1 Y2 0.001
45
Y
F52
(Resistance)
None(0.00): Not applicable
0.01 to 999
Variable
Ohm
Y Y1
Y2
None 12 Y
*1 The data setting range is variable. Refer to Section 2.2.
*2 The factory default setting varies depending on the shipping destination.
*3 The unit changes depending on the setting of C21.
*8 This function code is only for the torque vector control.
*9 FRN0025LM2A-4_ (11kW) to FRN0045LM2A-4_ (22kW): 0.3
Other: 0.0.
Содержание Frenic lift
Страница 1: ...LM2A series Reference Manual INR SI47 1909a E...
Страница 7: ......
Страница 13: ......
Страница 51: ...2 38...
Страница 221: ......
Страница 242: ...3 4 Programming Mode Chap 3 OPERATION USING TP A1 LM2 Figure 3 14 Screen transition for Op Monitor display example 3 21...
Страница 252: ......
Страница 254: ...URL http www fujielectric com...