Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 97
Classified as Business
Description: True
The MCU is operating in the Limp Home Mode.
False
The MCU is not operating in the Limp Home Mode.
When the MCU detects a serious impairment to its normal operation (inaccurate position signal,
IGBT switch problems, etc.), it enters Limp Home Mode. Limp Home Mode allows continued but
reduced operation as safely as possible given the impairment. The torque delivered will be
limited by the Limp Home Percentage, which is a percentage of the maximum torque possible at
each speed and voltage point. See the Danfoss Power Solutions EC- EM-PMI318B User
Manual for more details.
7.3.3.6
MCU Limp Home Mode History
dbc ref:
TCUStat3_MCULimpHomeModeHistory
lsb:
59
msb:
59
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
MCU
Limp Home Mode
has been set to True at some point since the last time MCU
power was cycled.
False
MCU
Limp Home Mode
has not been set to True at any point since the last time MCU
power was cycled.
7.3.3.7
MCU ADC Calibration Problem
dbc ref:
TCUStat3_MCU_ADCCalibrationProblem
lsb:
58
msb:
58
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The MCU’s ADC calibration integrity check failed.
False
The MCU’s ADC calibration integrity check passed.
This test is performed only at power up. Upon failure, the MCU uses default calibration data and
severely limits torque output capability. A power cycle is required to clear this error