Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 73
Classified as Business
7.3.2
TCU Status Message 2
ID:
PDU1: 08EErrss
16
PDU2: 08FFgess
16
11 bit: xrr1
16
From:
TCU
To:
VCU
Msg Rate:
50ms
Note:
The TCU will transmit this message immediately following the transmission of the
Status
Message 1
. The VCU will detect whether or not the message is received and will react as
appropriate.
64
63
62
61
60
59
58
57
Current Transmission Mode
Selected Gear
Upshift In
Progress
Downshift
In Progress
56
55
54
53
52
51
50
49
Upshift
Failed
Downshift
Failed
Slow
Upshift
Slow
Downshift
Shift
Disabled
Max Shift
Speed
Delta
Exceeded
Air
Pressure
Out of
Range
Forced
Gear
Engage
Torque
48
47
46
45
44
43
42
41
Motor
Speed
Mismatch
Error
Driveshaft
Speed
Mismatch
Error
MCU CAN
Active
MCU CAN
Timeout
MCU
Watchdog
Error
TCU
Command
Message 1
Error
TCU
Command
Message 1
Watchdog
Timeout
TCU
Command
Message 2
Error
40
39
38
37
36
35
34
33
TCU
Command
Message 2
Watchdog
Timeout
Trans
Temp
Warning
Trans
Temp Error
Trans
Temp
Limiting
Trans
Temp Read
Error
MCU
Inverter
Temp Read
Error
MCU Stator
Temp Read
Error
MCU Rotor
Temp Read
Error
32
31
30
29
28
27
26
25
MCU
Regen
Type Error
Factory Diagnostic Message msb
24
23
22
21
20
19
18
17
Factory Diagnostic Message lsb
16
15
14
13
12
11
10
9
Содержание ED-DT318B