Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 64
Classified as Business
7.2.2
TCU Command Message 2
Message:
Control Parameters
ID:
PDU1: 08EErrss
16
PDU2: 08FFgess
16
11 bit: xrr1
16
From:
VCU
To:
TCU
Msg Rate:
50ms
64
63
62
61
60
59
58
57
VCU Watchdog Counter 2
56
55
54
53
52
51
50
49
Acceleration Limit msB
48
47
46
45
44
43
42
41
Acceleration Limit lsB
40
39
38
37
36
35
34
33
Max Source Current
32
31
30
29
28
27
26
25
Max Sink Current
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
Driveshaft Speed msB
8
7
6
5
4
3
2
1
Driveshaft Speed lsB
7.2.2.1
VCU Watchdog Counter 2
dbc ref:
TCUCmd2_VCUWatchdogCounter_2
lsb:
57
msb:
60
Offset:
0
Scale Factor: 1
Min Value:
0