Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 74
Classified as Business
MCU
Power
Switches
Off
MCU
Invalid
Power
Supply
MCU Bad
Switch
MCU Bad
Position
Signal
MCU Phase
Current
Sensor
Error
MCU Stall
Condition
Active
MCU
Forced
Open Loop
MCU Turbo
Mode
8
7
6
5
4
3
2
1
MCU Using
Raw Speed
MCU Accel
Limited
MCU
Current
Trip Fault
Ileg/Ibus
MCU ABC
Phase
Order
MCU
System
Disabled In
Motion
MCU CAN
Limits
Active
MCU
Forced
Voltage
Control
7.3.2.1
Current Transmission Mode
dbc ref:
TCUStat2_CurrentTransmissionMode
lsb:
61
msb:
64
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
6
Units:
Enumerated
Description: TCU Current Mode of operation.
See
Transmission Mode
in
Traction Control Command
for details.
Note: This is not simply an echo of the
Transmission Mode
commanded by the
Traction
Control Command
. Operational conditions may delay or prevent a mode change.
7.3.2.2
Selected Gear
dbc ref:
TCUStat2_SelectedGear
lsb:
59
msb:
60
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
2
Units:
Enumeration
Description: The currently selected gear.
0: Neutral
1: Low
Содержание ED-DT318B