8.1
Setting Up the Software
Danfoss Power Solutions Motor Diagnostic Software requires 10 Megabytes of hard disk space on a Microsoft
Windows XP or later computer with a RS232 compliant COM port. A USB to RS232 Converter can be used to
connect the COM port, but it must be installed before the Danfoss Power Solutions Motor Diagnostic Software.
Table 8.1: Components of a Danfoss Power Solutions Motor Diagnostic Software Installation
Start Menu Label
Description
Danfoss Power
Solutions Motor
Controller
The main diagnostic software described in this section of the manual. Connects to a
Danfoss Power Solutions motor controller via an RS232 cable and provides an
environment to monitor and record the motor system conditions.
PowerPhase
®
DT2
Manual
This document.
TCUtoVCU_PDU1_LE
dbc file for the PowerPhase
®
DT2 system. The default configuration is for PDU1 29bit
headers and Little Endian
8.2
Starting the Software
After launching the Danfoss Power Solutions Motor Diagnostic Software, you are prompted (
) for the
COM port number and for the fastest baud rate you desire. Using the default top speed of 115200 is
recommended.
The software negotiates the baud rate with the controller each time it is started and finds the fastest baud rate
that can be maintained, so it will not necessarily operate at the maximum rate of 115200 baud. You can,
however, constrain it to a lower rate by setting that rate in the COM Port dialog box. Typically, this dialog box
only appears the first time you launch the software. It stores these settings and uses them each time it is
launched.
NOTICE
If the Danfoss Power Solutions Motor Diagnostic Software repeatedly asks you to choose a COM
Port then it is unable to store the information. Move the UqmMotor directory to a location on
your disk where the operating system allows the user to write.
If you want to change COM port or baud rate settings later, select
Actions > Choose COM Port
from the menu
).
Figure 8.12: Choose COM Port Dialog Box