The transmission lubricant temperature is equal to or greater than 120˚C.
False
The transmission lubricant temperature is within normal operating range.
7.3.2.23
Transmission Temperature Error
dbc ref:
TCUStat2_TransmissionTemperatureError
lsb:
38
msb:
38
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The transmission lubricant temperature has exceeded 120˚C for 30 minutes in the last
hour or the transmission lubricant temperature has exceeded 125˚C.
False
The transmission lubricant temperature has been within normal operating range for
more than 30 minutes in the last hour.
Warning: Excessive operation at lubricant temperatures in excess of 120˚C (1 hour in any 12
hour period) risks damage to the transmission.
7.3.2.24
Transmission Temperature Limiting
dbc ref:
TCUStat2_TransmissionTemperatureLimiting
lsb:
37
msb:
37
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The TCU is limiting the maximum torque allowed due to excessive transmission lubricant
temperature.