Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 66
Classified as Business
Scale Factor: 5
Min Value:
0
Max Value:
1275
Units:
Amps
Description: The maximum current the MCU is allowed to source to the battery when in regen.
Note 1: When this value is set to 0, the MCU reverts to its configured default value.
Note 2: The Limits Command Message to the MCU should only be sent when the Acceleration
Limit, Max Source Current, or Max Sink Current values are changed.
Note 3: The actual currents are expected to be on the order of ±10 A below 100 A or ±10%
above 100 A with some larger short term surges possible during large rapid torque
changes.
Note4: To avoid perturbations due to fluctuating limits, the command to the MCU will only be
updated at a 1s interval.
7.2.2.4
Max Sink Current
dbc ref:
TCUCmd2_MaxSinkCurrent
lsb:
25
msb:
32
Offset:
0
Scale Factor: 5
Min Value:
0
Max Value:
1275
Units:
Amps
Description: The maximum current the MCU is allowed to sink from the battery to drive the motor.
Note 1: When this value is set to 0, the MCU reverts to its configured default value.
Note 2: The Limits Command Message to the MCU should only be sent when the Acceleration
Limit, Max Source Current, or Max Sink Current values are changed.
Note 3: The actual currents are expected to be on the order of ±10 A below 100 A or ±10%
above 100 A with some larger short term surges possible during large rapid torque
changes.
Note4: To avoid perturbations due to fluctuating limits, the command to the MCU will only be
updated at a 1s interval.
7.2.2.5
Driveshaft Speed
dbc ref:
TCUCmd2_DriveshaftSpeed
lsb:
1
msb:
16
Offset:
0 (signed int)
Scale Factor: 1