Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 107
Classified as Business
Units:
Boolean
Description: True
The MCU’s Inverter is not enabled.
False
The MCU’s Inverter is enabled.
The motor will only be allowed to produce torque if the MCU’s Inverter is enabled. If the MCU
detects motor movement when the Inverter is not enabled, it will report a status of
MCU System
Disabled In Motion
.
Note: When the VCU sets the TCU to Neutral, the TCU will disable the MCU’s Inverter and
MCU
Not Enabled
will be True.
7.3.3.32
MCU Not Enabled History
dbc ref:
TCUStat3_MCUNotEnabledHistory
lsb:
33
msb:
33
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
MCU
Not Enabled
has been set to True at some point since the last time MCU power
was cycled.
False
MCU
Not Enabled
has not been set to True at any point since the last time MCU power
was cycled.
7.3.3.33
Transmission Output Speed
dbc ref:
TCUStat3_TransmissionOutputSpeed
lsb:
17
msb:
32
Offset:
0(signed int)
Scale Factor: 1
Min Value:
-16384
Max Value:
16383
Units:
rpm
Description: The transmission output speed to the driveshaft.
Note: Negative values indicate that the direction of travel is the opposite of the commanded
direction of travel – i.e.: if the commanded direction of travel is forward, a negative value
indicates that the vehicle is moving in the reverse direction and, if the commanded
direction of travel is reverse, a negative value indicates that the vehicle is moving in the
forward direction.
Содержание ED-DT318B