Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 61
Classified as Business
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The TCU will follow torque, speed and gear instructions from the VCU.
False
The TCU will remain in Neutral and will disable the MCU.
Note: The TCU will treat this condition as False if it does not have CAN communication with the
MCU.
7.2.1.6
Transmission Mode
dbc ref:
TCUCmd1_TransmissionMode
lsb:
49
msb:
52
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
6
Units:
Enumerated
Description: VCU to TCU Directed Mode of operation.
0: Neutral
Transmission is decoupled from the drive train and the motor is disabled
1: Reverse
The transmission does not have an explicit reverse gear. Reverse is achieved by placing the
transmission in Low gear and driving the motor in the reverse direction.
2: Forward Automatic
The TCU controls whether the transmission is in high or low (most common mode of operation).
3: Forward Low
The transmission is held in Low gear.
Note 1: The TCU will behave as if this field is Neutral if it does not have CAN communication with
the MCU.
Note 2: The TCU should be the Neutral state when voltage is not being supplied to the MCU. The
TCU should not exit the Neutral state until the power-up sequence is completed and the
TCU is reporting MCU status to the VCU.
Note 2: Transition to and from Reverse should only be allowed at extremely slow vehicle speeds
(transmission output speed <50 rpm).