Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 172
Status Signal
Time period
before
reacting
Typical Vehicle Controller Unit (VCU) Expected
Action
Recommended Service Action
TCU Torque
Section
X
Customer dependent - this is torque that the system
is delivering at the output of the driveshaft. It may
be used as a feedback signal to generate the VCU
torque request.
X
MCU Acceleration Limit
Section
X
Customer dependent - this is acceleration limit in
rpm/s at the output of the driveshaft. It may be used
as a feedback signal to check compliance with the
VCU acceleration limit.
X
MCU Voltage
Section
X
Customer dependent - this is voltage that the MCU is
either sinking (in drive) or sourcing (in regen). It may
be used as a feedback signal to check compliance
with the Battery Control Unit Voltage requirements.
X
MCU Current
Section
X
Customer dependent - this is voltage that the MCU is
either sinking (in drive) or sourcing (in regen). It may
be used as a feedback signal to check compliance
with the Battery Control Unit Current requirements.
X
MCU Leg Current
Section
X
Nothing
This is maximum current seen on any of the motor
phase leads within the most recent reporting period.
Provided for trouble shooting.
X
MCU Stall Safety
Percentage
Section
X
Customer dependent - this indicates how close the
motor is to a stall situation with the stall becoming
imminent as this number approaches 100. This is
more significant in small Danfoss Power Solutions
motors and has seldom been an issue with the larger
motors used in PowerPhase®DT2 systems.
X