Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 14
Classified as Business
2
Installation
This section provides information on mounting the drivetrain and controller in your vehicle. The installation
process for the Danfoss Power Solutions system is fairly straightforward but requires planning and caution to
avoid potential injury and/or damage to you or the equipment.
2.1
Avoiding Installation Problems
Please be aware of the following potential installation issues, which will cause damage or non-operational
equipment:
WARNING
Do not modify, or cut and re-solder, the Position cable length. If you need an alternate
length, contact Danfoss Power Solutions.
WARNING
Do not modify, or cut and re-solder, the Phase cable length. If you need an alternate
length, contact Danfoss Power Solutions.
WARNING
The DC cable length can be shortened if necessary. The customer is responsible for
the termination to the battery system and for ensuring proper termination of the
shielding is achieved.
WARNING
Ensure that the motor shaft will remain unobstructed during acceleration.
WARNING
Do not open the controller or motor housings.
CAUTION
Ensure that there is sufficient liquid cooling and flow rate of coolant.
2.2
Installing the MCU/Controller
This section describes the guidelines for installing the controller for optimum performance and maximum life.
Mounting dimensions of the liquid-cooled controller are shown in ICD drawing.
2.2.1
General Notes
The controller may be mounted in any orientation. Danfoss Power Solutions advises that the cable entry points
are NOT located on the top of the assembly, to avoid fluids wicking into the controller via the signal cable or user
interface cable. Secure the controller using four M10 bolts (user supplied), thru the mounting holes at the
corners of the case. The mounting points should be flat within 0.25 mm. The user is responsible for determining
the correct torque to apply to the M10 bolts. Controller is not to be mounted to the Motor Transmission
Assembly or support structure for the Motor Transmission Assembly.