Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 119
Classified as Business
Scale Factor: 0.4
Min Value:
0
Max Value:
100
Units:
%
Description: When this value reaches 100%, the stall safety limit trips and the MCU limits itself to 10% of its
rated torque for approximately 30 seconds.
Note: The likelihood of this occurring can be significantly reduced by configuring the MCU to use a low PWM
frequency (see the Stall data in the EC- EM-PMI318B User’s Manual for more details).
7.3.7.2
TCU Lubricant Temperature
dbc ref:
TCUStat7_TCULubricantTemperature
lsb:
49
msb:
56
Offset:
-40
Scale Factor: 1
Min Value:
-40
Max Value:
210
Units:
˚C
Description: The temperature of the transmission’s lubricant.
Note: Excessive use of the transmission at temperatures above 120˚C (more than 1 hour in any
12 hour period) may result in permanent damage to the transmission.
Note 2: The TCU will reduce the maximum allowed torque by 10% for each 1˚C of transmission
lubricant temperature above 125˚C.
7.3.7.3
MCU Inverter Temperature
dbc ref:
TCUStat7_MCUInverterTemperature
lsb:
41
msb:
48
Offset:
-40
Scale Factor: 1
Min Value:
-40
Max Value:
210
Units:
˚C
Description: The temperature of the MCU Inverter.
Note: The MCU will limit motor torque to keep this temperature within acceptable limits.