Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The High Voltage DC bus voltage is greater than the maximum for which the Danfoss
Power Solutions system is configured.
False
The High Voltage DC bus voltage is less than the maximum for which the Danfoss Power
Solutions system is configured.
If this condition is detected by the MCU, it will attempt to reduce the voltage by switching to the
Forced Voltage Control mode and limiting the available regeneration torque.
7.3.3.14
MCU Over Voltage Warning History
dbc ref:
TCUStat3_MCUOverVoltageWarningHistory
lsb:
51
msb:
51
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
MCU
Over Voltage Warning
has been set to True at some point since the last time MCU
power was cycled.
False
MCU
Over Voltage Warning
has not been set to True at any point since the last time
MCU power was cycled.
7.3.3.15
MCU Over Speed Warning
dbc ref:
TCUStat3_MCUOverSpeedWarning
lsb:
50
msb:
50
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
Motor speed is greater than the high speed warning threshold.
False
Motor speed is less than the high speed warning threshold.
If this condition is detected by the MCU, it will attempt to limit the speed by reducing the amount
of torque available.