Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 75
Classified as Business
2: High
3: Shift in progress
Note: The Error state indicates that the TCU is unable to determine the state of gear engagement
7.3.2.3
Upshift In Progress
dbc ref:
TCUStat2_UpshiftInProgress
lsb:
58
msb:
58
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
Gear shift to High gear is in progress
False
Gear shift to High gear is not in progress
7.3.2.4
Downshift In Progress
dbc ref:
TCUStat2_DownshiftInProgress
lsb:
57
msb:
57
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
Gear shift to Low gear is in progress
False
Gear shift to Low gear is not in progress
7.3.2.5
Upshift Failed
dbc ref:
TCUStat2_UpshiftFailed
lsb:
56
msb:
56
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean