Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 77
Classified as Business
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The previous shift to High shift required an excessive amount of time
False
The previous attempted shift to High gear was accomplished in a normal amount of time
7.3.2.8
Slow Downshift
dbc ref:
TCUStat2_SlowDownshift
lsb:
53
msb:
53
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The previous shift to Low gear required an excessive amount of time
False
The previous attempted shift to Low gear was accomplished in a normal amount of time
7.3.2.9
Shift Disabled
dbc ref:
TCUStat2_ShiftDisabled
lsb:
52
msb:
52
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The ability to change from High to Low gear, from Low to High, or from Neutral to either
Low or High is disabled.
False
The ability to change gears is not disabled
Note: Once gear shifting is disabled, it will not be reenabled until the entire system has been
power cycled.
Warning: the system should never be power cycled while the vehicle is in motion.
7.3.2.10
Max Shift Speed Delta Exceeded
dbc ref:
TCUStat2_MaxShiftSpeedDeltaExceeded