8.3.2
Status Group
Figure 8.14: Status Group
The status group (
) is an important area of the front panel because it shows the status of the motor
system at that moment. Conditions are monitored and problems are reported that are currently affecting the
normal operation of the motor system. Whenever a red light is showing in the status group, the controller could
be severely limited in operation.
shows the conditions that can cause red and yellow lights in the status
group.
Table 8.4: Status Group Problems
RED LIGHT
EEROM failed
The persistent memory on board the controller has failed or is not
programmed. The controller cannot operate.
Bad System Configuration
The system configuration information in the persistent memory is unusable.
The controller cannot operate.
Unit not Calibrated
The calibration data in the persistent memory is not present. The controller is
severely limited in operation.
Bad ADC Calibration
The calibration values are out of specification. Default calibration values are
being used, and the controller is severely limited in operation.
Sensor voltage invalid
The voltage that powers the current and temperature sensors is invalid. This
is normal when high voltage is not present, but if high voltage is present
then the controller is severely limited.
Inverter Faulted
One or more inverter/controller modules are presently faulted. This is normal
when high voltage is not present. However, if high voltage is present, the
controller is severely limited.