Description: The value of this enumeration is defined by the customer specific configuration. It will be
matched to the MCU. If the MCU is not of the appropriate type, TCU System Type will be set to
“Unknown” (0).
The VCU should verify that the TCU System Type and VCU System Type Revision are correct for
the VCUs configuration.
7.3.1.4
TCU System Type Revision
dbc ref:
TCUStat1_TCUSystemTypeRev
lsb:
33
msb:
40
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
255
Units:
Enumeration
Description: The value of this enumeration is defined by the number of changes that have been made to the
system configuration.
The VCU should verify that the TCU System Type and VCU System Type Revision are correct for
the VCUs configuration.
7.3.1.5
TCU Major Version
dbc ref:
TCUStat1_TCUMajorVersion
lsb:
29
msb:
32
Offset:
0
Scale Factor: 1
Min Value:
1
Max Value:
15
Units:
Integer
Description: TCU Code Major Version Number.
7.3.1.6
TCU Minor Version
dbc ref:
TCUStat1_TCUMinorVersion
lsb:
21
msb:
28
Offset:
0
Scale Factor: 1
Min Value:
1
Max Value:
255
Содержание ED-DT318B