Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 84
Classified as Business
False
The TCU is not limiting the maximum torque allowed due to excessive transmission
lubricant temperature.
7.3.2.25
Transmission Temperature Read Error
dbc ref:
TCUStat2_TransmissionTemperatureReadError
lsb:
36
msb:
36
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The TCU detected either an open or a short in the transmission lubricant temperature
sensor.
False
The transmission lubricant temperature sensor is working properly.
7.3.2.26
MCU Inverter Temperature Read Error
dbc ref:
TCUStat2_MCUInverterTemperatureReadError
lsb:
35
msb:
35
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The TCU detected either an open or a short in the MCU Inverter temperature sensor.
False
The MCU Inverter temperature sensor is working properly.
7.3.2.27
MCU Stator Temperature Read Error
dbc ref:
TCUStat2_MCUStatorTemperatureReadError
lsb:
34
msb:
34
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean