Description: True
The TCU detected either an open or a short in the MCU Stator temperature sensor.
False
The MCU Stator temperature sensor is working properly.
7.3.2.28
MCU Rotor Temperature Read Error
dbc ref:
TCUStat2_MCURotorTemperatureReadError
lsb:
33
msb:
33
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The TCU detected either an open or a short in the MCU Rotor temperature sensor.
False
The MCU Rotor temperature sensor is working properly.
7.3.2.29
MCU Regen Type Error
dbc ref:
TCUStat2_MCURegenTypeError
lsb:
32
msb:
32
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: 0: MCU is configured for New Style Regen
1: MCU is not configured for New Style Regen
In Old Style Regen, the MCU will continue to produce regen torque until speed equals 0rpm
In New Style Regen, the MCU will only produce regen torque if the motor speed exceeds the
Forward or Reverse speed limits.
The default setting for the MCU is new style regen. The TCU is designed to operate with New
Style Regen, therefore the TCU will not operate if the system is in Old Style Regen.
7.3.2.30
Factory Diagnostic Message
dbc ref:
TCUStat2_FTYDiagnosticMessage
lsb:
17
msb:
31
Offset: