Table 3.2: RS232 Communications pinout
RS232 9 pin D Connector
Signal
Pin
Rx
2
Tx
3
Ground
5
When deciding where to position the Diagnostic Connector the user should take into consideration that, when
in operation, the technician using the port will require cabling from the port to a laptop computer. An additional
consideration is that voltage from the vehicles low 24 V electrical system will be present on pin 16 of the
Diagnostic Connector.
Therefore, the Connector should be positioned inside the vehicle’s cabin in a location that will provide easy
access while the vehicle is in motion, but will not interfere with the driver or passengers while in use and will
protect the driver and passengers from the possibility of electrical shocks.
Table 3.3: DT2 Diagnostic Connector (Connector 4) pinout
Pin Assignment
Wire
Connector 3
Note
MCU CAN Shield
14020-019
11
MCU CAN +
14020-019
9
120Ω Termination to
MCU CAN -
Vgnd (TCU)
18 AWG
24 V Battery negative
VCU CAN +
14020-019
1 or 4
RS232 Transmit TxD 14020-019
12
RS232 Shield
14020-019
14
MCU CAN -
14020-019
10
120Ω Termination to
MCU CAN +
FEPS
18 AWG
15
VCU CAN Shield
14020-019
3 or 6
VCU CAN -
14020-019
2 or 5
RS232 Receive RxD 14020-019
13
Vbatt (TCU)
18 AWG
24 V Battery positive
–
use of a 10A fuse is recommended