7.3.3.34
MCU Motor Speed
dbc ref:
TCUStat3_MCUMotorSpeed
lsb:
16
msb:
1
msb:
56
Offset:
0(signed int)
Scale Factor: 1
Min Value:
-16064
Max Value:
16064
Units:
rpm
Description: The rotational speed of the motor.
Note 1: Negative values indicate that the direction of travel is the opposite of the commanded
direction of travel – i.e.: if the commanded direction of travel is forward, a negative value
indicates that the vehicle is moving in the reverse direction and, if the commanded
direction of travel is reverse, a negative value indicates that the vehicle is moving in the
forward direction.
Note 2: When the transmission is in high gear,
MCU
Motor Speed
will be equal to
Transmission
Output Speed
. When the transmission is in low gear (forward or reverse),
Motor Speed
will be equal to 3.529 *
Transmission Output Speed
. When the transmission is in
Neutral, there is no correlation between
MCU
Motor Speed
and
Transmission Output
Speed
.