Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 55
Classified as Business
6.3
RS232 Communications
The Danfoss Power Solutions Motor Diagnostic Software (
Section
) communicates to the motor system through
the RS232 communication pins (7, 15 & 8) of the DT2 Diagnostic Connector (Connector 4 in
). As with
the TCU to MCU CAN bus, the RS232 serial bus is routed to the 16 pin User Interface connector (Connector 3 in
) via the TCU to MCU Interface Cable (Cable C in
). The customer is responsible for the wiring
from the Drivetrain Interface Connector to the DT2 Diagnostic Connector.
6.4
DT2 Diagnostic Connector
The DT2 Diagnostic connector provides access to the CAN busses used by the PowerPhase
®
DT2 system for
monitoring bus traffic, configuring the TCU, updating TCU and MCU software, and use in diagnosing issues with
the TCU. It also provides an RS232 compliant connection to the MCU for diagnostic and configuration purposes.
Wiring for the Diagnostic Connector is covered in
Section 3.6
Содержание ED-DT318B
Страница 185: ......