Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 146
Classified as Business
Table 8.12: DAQ Set Up Components
Label
Description
Directory:
Browse button
Enter the directory where DAQ files should be written. Browse brings up a File Open
dialog box. Use it to point to the directory you want to use.
Include in Name
Text that you want included into the DAQ filename. It will include the date, this text,
and an incrementing number.
Trigger WHEN:
Select the triggers desired. If you select a trigger that depends on a trigger level then
click on the Trigger Level button to set the value for that trigger.
Re-enable trigger
Re-enables the trigger immediately after a DAQ data file has been completely
downloaded.
NOTICE You must ensure that the triggers selected are not still active when the re-
enable occurs. For example, a trigger of “Position signal is bad” if re-enabled
immediately will also immediately cause another file to be gathered. This will
continue until you manually cancel or until your disk is full.
Data Spacing and
Length
Select the sampling rate from 80 microseconds, to 6 milliseconds. This also selects the
total amount of time that data is collected, from 140.2 msec to 3.625 sec.
Trigger Point
within Data Buffer
Move the slide bar to indicate how much of the data you want before the trigger
event and how much after it.
Load from Config
File
This button is the equivalent of the menu choice Actions > Daq Configuration > Load
from File. It loads a QDC configuration file into the dialog box.
Save to Config File
Button is the equivalent of the menu choice Actions > Daq Configuration > Save to
File. It saves the current configuration to a QDC file in the location you specify.
Set Trigger Levels
Button brings up the DAQ Trigger Level dialog box. It is also possible to reach the
Trigger Level dialog box directly from the front panel through Action > Daq
Configuration > Edit Levels.
shows this dialog box.
Set to Default
Values
Button resets all DAQ Configuration settings to their default values.
The “Trigger Thresholds” dialog box (
) sets the levels at which several triggers will occur. Note that the
RPM Speed trigger is a SIGNED trigger level. If the motor is rotating in reverse, a positive trigger value can never
cause a trigger.
8.5.2
DAQ Set Up Example
The DAQ feature of the Danfoss Power Solutions Motor Diagnostic Software is very useful when you need to
diagnose a dynamic problem in your system. Because the Danfoss Power Solutions motor is connected to most
of your system’s components, its measurements can help you find problems. For example, if your soft-start
functionality is connecting and then disconnecting a short time later, Danfoss Power Solutions Motor’s DAQ can
be used to trigger and collect fast data around this event so that you can see what your high voltage bus is