Torque matching problem
If this condition persists, the controller is indicating that it is unable to control
the motor to the desired torque. This could be because the motor has partially
demagnetized.
Limiting acceleration
Torque is being limited due to the acceleration limit in force.
Actively Damping
The Active Damping Control is altering the torque to damp out a drive train
oscillation.
Regen disabled
The Regen Switch is open and regeneration power is impossible. The switch
will close when the internal and external voltage measurements close to
within 25V of each other
System Halt
The system is not operational. Voltage must rise to the minimum battery level
before the system becomes operational.
ManuInfo invalid
The manufacturing information present in the inverter is invalid. This may
mean that there is a problem with the inverter’s EEROM.
Event Log disabled
The Event Log is inoperable. This does not affect motor operation.
8.3.3
Menu Bar and Toolbar
The diagnostic software has a menu and toolbar to access other functionality beyond condition and
measurement information.
describes the menu’s choices and shows those that have Toolbar buttons.
Figure 8.15: Menu Bar and Toolbar
Table 8.5: Menu and Toolbar Descriptions
Menu Choice
Button
Description
File
Recent Files
Shows the four most recent log or DAQ files written by the
software.
Exit
Exits the diagnostic software.