Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 69
Classified as Business
Min Value:
0
Max Value:
15
Units:
Enumeration
Description: The system type of the MCU
Danfoss Part
Former UQM Part
Description
0: Unknown
1: EM-PMI318-T350-255V
PowerPhase
®
HD-220 HD1 & 2 turn motor
2: EM-PMI318-T360-425V
PowerPhase
®
HD-250 HD1 & 3 turn motor
3: EM-PMI318-T400-255V
PowerPhase
®
HD-950T HD1 & 3 turn motor (Low Voltage)
4: EM-PMI318B-T440E-255V PowerPhase
®
HD-225 HD2 & 2 turn motor
5: EM-PMI318B-T520E-465V PowerPhase
®
HD-255 HD2 & 3 turn motor
6: Undefined
7: EM-PMI318B-T360-465V PowerPhase
®
HD-251 HD2 & 3 turn varnished motor
8-15: Undefined
7.3.1.2
Watchdog Counter
dbc ref:
TCUStat1_TCUWatchdogCounter
lsb:
57
msb:
60
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
15
Units:
Rolling Count
Description: The
Watchdog Counter
is used to detect missed messages from the TCU to the VCU and to
detect issues with VCU messaging procedures.
In each successive
Status 1 Message
, the
Watchdog Counter
will be the
Watchdog Counter
of
the previous
Status 1 Message
+ 1. If the
Watchdog Counter
of the previous
Status 1 Message
was 15, the
Watchdog Counter
will be reset to 0.
The VCU should monitor
Watchdog Counter
for
any irregularities and react accordingly.
7.3.1.3
TCU System Type
dbc ref:
TCUStat1_TCUSystemType
lsb:
41
msb:
56
Offset:
0
Scale Factor: 1
Min Value:
0 (“Unknown System Type”)
Max Value:
65535
Units:
Enumeration
Содержание ED-DT318B