Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 106
Classified as Business
False
MCU
Over Bus Current
has not been set to True at any point since the last time MCU
power was cycled.
7.3.3.29
MCU Over Leg Current
dbc ref:
TCUStat3_MCUOverLegCurrent
lsb:
36
msb:
36
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The motor phase currents are exceeding their normal operating parameters.
False
The motor phase currents are within their normal operating parameters.
7.3.3.30
MCU Over Leg Current History
dbc ref:
TCUStat3_MCUOverLegCurrentHistory
lsb:
35
msb:
35
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
MCU
Over Leg Current
has been set to True at some point since the last time MCU
power was cycled.
False
MCU
Over Leg Current
has not been set to True at any point since the last time MCU
power was cycled.
7.3.3.31
MCU Not Enabled
dbc ref:
TCUStat3_MCUNotEnabled
lsb:
34
msb:
34
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1