CAUTION
Ensure the O-Rings are in-place or installed before connection to the controller.
CAUTION
Ensure the O-Rings are not pinched or nicked during installation.
WARNING
Ensure that the power is off before connecting the power cables.
WARNING
Ensure that the phase cables and DC cables are routed and restrained to prevent
insulation damage.
WARNING
Do not use Locktite
®
or similar products when securing the High Voltage DC or the 3
phase AC cables to the inverter.
The use of Locktite
®
in these locations will increase the resistance of the connection
and may result in melting of the overmolding.
DANGER
Failure to orient the power lug connections correctly can cause short to chassis.
DANGER
Do not connect either the positive or negative high voltage bus to the chassis, motor
cases, or controller. Catastrophic damage will occur. Provide sufficient insulation on all
power terminals for safety.
Section 3.1.3
DANGER
It is the customer’s responsibility to disable high voltage DC when the Danfoss Power
Solutions HVIL indicates that either the inverter or the motor termination covers is
open.
CAUTION
The user is responsible for proper HVIL actions and for disabling the DC high voltage
power when the HVIL circuit is open.
Section 3.2
WARNING
The user is responsible for providing and installing a ground strap from the motor to
the controller. Without a ground cable, erratic operation can occur.